Non-Intumescent Fire-Retardant Coating E60-2

    • Product Name: Non-Intumescent Fire-Retardant Coating E60-2
    • Chemical Name (IUPAC): Ammonium polyphosphate
    • CAS No.: 42699-05-2
    • Chemical Formula: C4H8Cl2O2
    • Form/Physical State: Liquid
    • Factroy Site: West Ujimqin Banner, Xilingol League, Inner Mongolia, China
    • Price Inquiry: sales9@bouling-chem.com
    • Manufacturer: Bouling Coating
    • CONTACT NOW
    Specifications

    HS Code

    802721

    Product Name Non-Intumescent Fire-Retardant Coating E60-2
    Type Non-intumescent fire-retardant coating
    Fire Resistance Rating E60
    Application Surface Steel structures
    Color White
    Finish Matte
    Drying Time Surface 1-2 hours (at 20°C)
    Theoretical Coverage 1.5-2.0 kg/m²
    Density 1.35 g/cm³
    Thickness Per Coat 300-600 μm/dry
    Application Method Brush, roller, or spray
    Volatile Organic Compounds <80 g/L
    Adhesion Strength ≥ 1.0 MPa (on steel)
    Shelf Life 12 months (unopened, cool storage)
    Water Resistance Good

    As an accredited Non-Intumescent Fire-Retardant Coating E60-2 factory, we enforce strict quality protocols—every batch undergoes rigorous testing to ensure consistent efficacy and safety standards.

    Packing & Storage
    Packing The Non-Intumescent Fire-Retardant Coating E60-2 is packaged in a 20-liter white metal drum with detailed safety labeling.
    Container Loading (20′ FCL) 20′ FCL holds 16–20 MT of Non-Intumescent Fire-Retardant Coating E60-2, packed in sealed drums or IBC tanks.
    Shipping The Non-Intumescent Fire-Retardant Coating E60-2 is shipped in tightly sealed, labeled containers suitable for chemicals, typically in 20-liter drums. It requires upright storage, protection from extreme temperatures, and compliance with relevant safety regulations. Detailed handling and safety instructions are provided with each shipment to ensure safe transport and storage.
    Storage Non-Intumescent Fire-Retardant Coating E60-2 should be stored in tightly sealed original containers in a cool, dry, and well-ventilated area, away from direct sunlight, heat sources, and ignition points. Keep away from incompatible substances such as strong oxidizers. Avoid freezing and excessive temperatures. Ensure containers are clearly labeled and kept upright to prevent leaks or spills.
    Shelf Life Non-Intumescent Fire-Retardant Coating E60-2 has a shelf life of 12 months when stored in unopened, original containers.
    Application of Non-Intumescent Fire-Retardant Coating E60-2

    Thermal Stability: Non-Intumescent Fire-Retardant Coating E60-2 with high thermal stability is used in commercial steel structures, where it provides sustained fire resistance up to 600°C.

    Dry Film Thickness: Non-Intumescent Fire-Retardant Coating E60-2 with a dry film thickness of 250 µm is used in public transportation terminals, where it ensures compliance with fire safety regulations.

    VOC Content: Non-Intumescent Fire-Retardant Coating E60-2 with low VOC content (<50 g/L) is used in healthcare facility interiors, where it reduces indoor air pollution and meets environmental standards.

    Adhesion Strength: Non-Intumescent Fire-Retardant Coating E60-2 with enhanced adhesion strength is used in power plant infrastructure, where it prevents delamination under thermal cycling.

    Moisture Resistance: Non-Intumescent Fire-Retardant Coating E60-2 with high moisture resistance is used in underground parking garages, where it maintains fire protection integrity in damp conditions.

    Chemical Resistance: Non-Intumescent Fire-Retardant Coating E60-2 with strong chemical resistance is used in laboratory wall systems, where it resists degradation from solvents and acids.

    Surface Hardness: Non-Intumescent Fire-Retardant Coating E60-2 with increased surface hardness is used in industrial warehouse floors, where it reduces abrasion and extends service life.

    Color Retention: Non-Intumescent Fire-Retardant Coating E60-2 with superior color retention is used in high-traffic corridors, where it maintains appearance after fire exposure.

    Application Temperature: Non-Intumescent Fire-Retardant Coating E60-2 suitable for application at 5–35°C is used on-site during variable weather conditions, where it allows flexible installation schedules.

    Curing Time: Non-Intumescent Fire-Retardant Coating E60-2 with rapid curing time (<2 hours) is used in modular building construction, where it accelerates project completion and turnover.

    Free Quote

    Competitive Non-Intumescent Fire-Retardant Coating E60-2 prices that fit your budget—flexible terms and customized quotes for every order.

    For samples, pricing, or more information, please contact us at +8615651039172 or mail to sales9@bouling-chem.com.

    We will respond to you as soon as possible.

    Tel: +8615651039172

    Email: sales9@bouling-chem.com

    Get Free Quote of Bouling Coating

    Flexible payment, competitive price, premium service - Inquire now!

    Certification & Compliance